P
AtLeastOneEquipmentOnDuty
|
FailureDefinitionId
|
There should be at least one equipment on duty.
|
|
P
ClassificationNotSetInFamily
|
FailureDefinitionId
|
A calculation did not complete because the Classification parameter in the Mechanical Equipment family is not set.
|
|
P
DemandFlowAndPressureLossNotSetInLossFamily
|
FailureDefinitionId
|
A calculation did not complete because the pressure loss value for element is not set. Select the element and enter a value for the Pressure Loss.
|
|
P
DemandFlowNotSetInLossFamily
|
FailureDefinitionId
|
A calculation did not complete because the Demand Flow for the element is not set.
|
|
P
DuctFittingAndAccessoryPressureDropCalculatorNotAvailable
|
FailureDefinitionId
|
Duct Fitting/Accessory Pressure Drop Calculator Not Available: [Calculator Name]
|
|
P
DuctPressureDropCalculatorNotAvailable
|
FailureDefinitionId
|
Duct Pressure Drop Calculator Not Available: [Calculator Name]
|
|
P
ExtraPumpSet
|
FailureDefinitionId
|
More than one parallel pump set defined for the same loop. Verify the flow distribution and delete the extra set, if desired.
|
|
P
FlowAndPressureCalculationMethodHasBeenImproved
|
FailureDefinitionId
|
During upgrade pressure drop calculations for hydronic piping systems using Simplified Colebrook or Custom Calculation methods have been recalculated using the Colebrook equation.
|
|
P
HydraulicSeparationAmbiguity
|
FailureDefinitionId
|
Unable to hydraulically separate until the system has flow.
|
|
P
HydraulicSeparationOfOneSystem
|
FailureDefinitionId
|
Unable to hydraulically separate the loop when both supply and return are assigned to the same system. Try again with both start and end selected.
|
|
P
InvalidNumberOfMechanicalEquipmentOnDuty
|
FailureDefinitionId
|
The number of on duty equipment must be less than or equal to the number of available equipments.
|
|
P
LoopSeparationNotCompleted
|
FailureDefinitionId
|
The loop separation is not completed yet. Only one side of the secondary/tertiary loop is separated. In order to correctly calculate the flow and pressure loss, please check and separate the other end of the loop.
|
|
P
MechanicalEquipmentSetBeingDeleted
|
FailureDefinitionId
|
The mechanical equipment set was deleted because it no longer contained any members.
|
|
P
Network_ElementNodeIsNotPartOfNetwork
|
FailureDefinitionId
|
The calculation could not be executed as configured. At least one of the elements in this network uses a node that is not part of the network.
|
|
P
Network_NodePropertyNotSet
|
FailureDefinitionId
|
The calculation could not be executed as configured. Specify a constraint property set for the following input or output node(s).
|
|
P
Network_NoInputNode
|
FailureDefinitionId
|
The calculation could not be executed as configured. Select an input node before analyzing this network.
|
|
P
Network_NoOutputNode
|
FailureDefinitionId
|
The calculation could not be executed as configured. Select an output node before analyzing this network.
|
|
P
Network_NoPressureConstraint
|
FailureDefinitionId
|
The calculation could not be executed as configured. Each network requires at least 1 pressure constraint. Specify the pressure constraint.
|
|
P
Network_NotEnoughElements
|
FailureDefinitionId
|
The calculation could not be executed as configured. Specify at least 3 elements before analyzing this network.
|
|
P
Network_NotEnoughNodes
|
FailureDefinitionId
|
The calculation could not be executed as configured. Specify at least 4 elements before analyzing this network.
|
|
P
Network_NotFullyConnected
|
FailureDefinitionId
|
The network is not well connected. Some elements may have unexpected flow and pressure loss values.
|
|
P
Network_OverConstrained
|
FailureDefinitionId
|
The calculation could not be executed as configured. The Pressure and Flow Rate combined constraint requires at least 2 other pressure or flow constraints. Specify additional constraints.
|
|
P
NetworkCanNotDeterminCriticalPath
|
FailureDefinitionId
|
The calculation has completed, but there may be an error in determining the critical path. Verify that demand flow is specified for all required elements.
|
|
P
NetworkDefaultToPressure
|
FailureDefinitionId
|
The network uses the default pressure.
|
|
P
NetworkDefaultToReynolds
|
FailureDefinitionId
|
The network uses the default Reynolds number.
|
|
P
NetworkEnergyEquationNotConverge
|
FailureDefinitionId
|
The energy calculation could not be performed.
|
|
P
NetworkErrorCalculatingPressure
|
FailureDefinitionId
|
The pressure calculation could not be performed.
|
|
P
NetworkErrorElementWithDownUpStreamNode
|
FailureDefinitionId
|
The network needs an input or output element to perform the calculation.
|
|
P
NetworkErrorExtractCurveData
|
FailureDefinitionId
|
The calculation could not be performed. Verify the pump curve data.
|
|
P
NetworkErrorModelTooBig
|
FailureDefinitionId
|
The size of the network exceeds the current limit for flow/pressure analysis. In the Mechanical Settings dialog, under Pipe Settings - Calculation, disable the option to Use analysis for closed loop hydronic networks.
|
|
P
NetworkErrorOverConstrained
|
FailureDefinitionId
|
The calculation could not be performed due to overconstrained flow condition in the network.
|
|
P
NetworkExtraPumpOutsideSet
|
FailureDefinitionId
|
Flow calculations do not calculate this pump together with the other pumps as one equipment set. Verify the flow distribution and add the pump to the equipment set, if desired.
|
|
P
NetworkInconsistentDemandFlow
|
FailureDefinitionId
|
The specified flow on this equipment is inconsistent with the other equipment in this branch. The branch flow is calculated based on the maximum specified value.
|
|
P
NetworkMinorLossNotConverge
|
FailureDefinitionId
|
The minor loss calculation could not be performed.
|
|
P
NetworkPressureNotConverge
|
FailureDefinitionId
|
The calculation could not be performed. Verify the pressure on the input element.
|
|
P
NetworkUnderConstrained
|
FailureDefinitionId
|
The network is under constrained. You may specify the design flow value in the missing branches, or cap the open ends.
|
|
P
PipeConnectorsAreNotLined
|
FailureDefinitionId
|
A calculation did not complete because the connectors used by this family to connect to the network are not linked.
|
|
P
PipeFittingAndAccessoryPressureDropCalculatorNotAvailable
|
FailureDefinitionId
|
Pipe Fitting/Accessory Pressure Drop Calculator Not Available: [Calculator Name]
|
|
P
PipePressureDropCalculatorNotAvailable
|
FailureDefinitionId
|
Pipe Pressure Drop Calculator Not Available: [Calculator Name]
|
|
P
PlumbingFlowCalculatorNotAvailable
|
FailureDefinitionId
|
Plumbing Flow Calculator Not Available: [Calculator Name]
|
|
P
PressureLossNotSetInLossFamily
|
FailureDefinitionId
|
A calculation did not complete because the pressure loss value for the source equipment is not set for the network.
|
|
P
PumpPressureNotComputed
|
FailureDefinitionId
|
The calculated pressure drop of this pump is not computed because the critical path is not a closed loop. Check to see if there are other pumps intended for use within a secondary/tertiary loop. Use the Add Separation tool to define the secondary/tertiary loop.
|
|
P
SeparationNotAtJunction
|
FailureDefinitionId
|
This hydraulic loop is not separated at any junction. Use the Remove Separation tool to clean up undesired hydraulic separations.
|
|
P
SeparationWithOddJunction
|
FailureDefinitionId
|
Hydraulic separation requires an even number of junctions on the header pipe for accurate calculations. Add or remove junctions to complete the separation.
|