P
AreaReinforcementOutSideOfHost
|
FailureDefinitionId
|
Area Reinforcement is sketched completely outside of its host.
|
|
P
AreaReinforcementRegenFail
|
FailureDefinitionId
|
Can't regenerate Area Reinforcement.
|
|
P
AreaReinforcementsCollision
|
FailureDefinitionId
|
Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.
|
|
P
AreaReinforcementWrongHost
|
FailureDefinitionId
|
Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.
|
|
P
BarsTooCloseNumber
|
FailureDefinitionId
|
Bars are too close together. Decrease the Number Of Lines parameter.
|
|
P
BarsTooCloseSpacing
|
FailureDefinitionId
|
Bars are too close together. Increase the Maximum Spacing parameter.
|
|
P
BarsTooSparseSpacing
|
FailureDefinitionId
|
Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.
|
|
P
CannotPlaceAreaReinforcement
|
FailureDefinitionId
|
Can't find a host for Area Reinforcement.
|
|
P
CannotPlaceAreaReinforcementWarn
|
FailureDefinitionId
|
Can't find a host for Area Reinforcement.
|
|
P
CannotPlaceAreaReininforcement
|
FailureDefinitionId
|
Can't find a host for Area Reinforcement.
|
|
P
CannotPlaceAreaReininforcementWarn
|
FailureDefinitionId
|
Can't find a host for Area Reinforcement.
|
|
P
CannotPlacePathReinforcement
|
FailureDefinitionId
|
Can't find a host for Path Reinforcement.
|
|
P
CannotPlacePathReinforcementWarn
|
FailureDefinitionId
|
Can't find a host for Path Reinforcement.
|
|
P
CannotPlacePathReininforcement
|
FailureDefinitionId
|
Can't find a host for Path Reinforcement.
|
|
P
CannotPlacePathReininforcementWarn
|
FailureDefinitionId
|
Can't find a host for Path Reinforcement.
|
|
P
CannotUseAreaReinforcementHookTypeStyle
|
FailureDefinitionId
|
At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
|
|
P
CannotUsePathReinforcementHookTypeStyle
|
FailureDefinitionId
|
At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
|
|
P
DPartReinfDeletedEditDivision
|
FailureDefinitionId
|
Edits to the model will cause some Reinforcement hosted on Parts to be deleted.
|
|
P
DPartReinforcementDeleted
|
FailureDefinitionId
|
Reinforcement hosted on highlighted Parts will be deleted.
|
|
P
HostFlagAreaOff
|
FailureDefinitionId
|
|
|
P
HostFlagAreaOn
|
FailureDefinitionId
|
The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.
|
|
P
HostFlagPathOff
|
FailureDefinitionId
|
|
|
P
HostFlagPathOn
|
FailureDefinitionId
|
|
|
P
PathReinforcementWrongHost
|
FailureDefinitionId
|
Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.
|
|
P
RebarSystemOffset
|
FailureDefinitionId
|
Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.
|
|
P
ThinHostFloor
|
FailureDefinitionId
|
Rebar Cover Top and Bottom are too large for host.
|
|
P
ThinHostFloorError
|
FailureDefinitionId
|
Rebar Cover Top and Bottom are too large for host.
|
|
P
ThinHostWall
|
FailureDefinitionId
|
Rebar Cover Interior and Exterior are too large for host.
|
|
P
ThinHostWallError
|
FailureDefinitionId
|
Rebar Cover Interior and Exterior are too large for host.
|