P
Coefficient
|
double
|
The calculated coefficient of this segment, dimensionless.
|
|
P
Flow
|
double
|
The calculated flow of this segment, in ft^3/s. The positive value means the flow is from the start to the end node, the negative value means opposite direction.
|
|
P
FlowState
|
PipeFlowState
|
The calculated flow state of this segment.
|
|
P
FrictionFactor
|
double
|
The calculated friction factor of this segment, dimensionless.
|
|
P
IsCriticalPath
|
bool
|
Verifies if the segment is on the critical path.
|
|
P
IsValidObject
|
Boolean
|
Specifies whether the .NET object represents a valid Revit entity.
|
|
P
PressureDrop
|
double
|
The calculated pressure drop of this segment, in kg/(ft*s^2).
|
|
P
RelativeRoughness
|
double
|
The relative roughness of this segment, dimensionless.
|
|
P
ReynoldsNumber
|
double
|
The Reynolds number of this segment, dimensionless.
|
|
P
SectionNumber
|
int
|
The section this segment belongs to.
|
|
P
Velocity
|
double
|
The calculated velocity of this segment, in ft/s.
|
|
P
VelocityPressure
|
double
|
The calculated velocity pressure of this segment, in kg/(ft*s^2).
|