2027 Members
Changes 0
M

AnalyticalModelFailures Properties

Name Return Type Description
P AdjustCurveTooShort FailureDefinitionId AdjustCurve is too short.
P AdjustEdgeTooShort FailureDefinitionId AdjustEdge is too short.
P AdjustEdgeTooShortErr FailureDefinitionId AdjustEdge is too short - continuable error version.
P AdjustEdgeTooShortWarn FailureDefinitionId AdjustEdge is too short.
P AnalyticalBeamSlabWarning FailureDefinitionId Beam and Slab Analytical Models do not have the same Analytical Projection Plane.
P AnalyticalCurvedPanelNotValid FailureDefinitionId Analytical Curved Panel is not valid.
P AnalyticalDiscrepancyWarning FailureDefinitionId Distance between Analytical and Physical Models of Structural Element is beyond tolerance of [Value]
P AnalyticalElementsInvalidAfterUpgrade FailureDefinitionId One or several analytical elements have become invalid during the upgrade process and will be deleted.
P AnalyticalGapWarning FailureDefinitionId Detected physical connection between Structural Elements, but did not detect Analytical intersection.
P AnalyticalLinkJoinedNodes FailureDefinitionId Analitycal Link is invalid. Reference nodes have been joined.
P AnalyticalLinkNotConnected FailureDefinitionId Analytical Link has lost one or more references.
P AnalyticalMemberInstability FailureDefinitionId Possible Member Instability, based on Release Conditions
P AnalyticalModelInstability FailureDefinitionId Possible Model Instability
P AnalyticalModelIsIncorrect FailureDefinitionId Analytical Model is not created for the structural element.
P AnalyticalPanelNotPlanar FailureDefinitionId Analytical Panel is not planar.
P AnalyticalPanelNotVisible FailureDefinitionId Analytical Panel is not visible in the current view.
P AnalyticalPanelSplitNothing FailureDefinitionId The Analytical Panel cannot be split. The cutting plane does not intersect the panel in a way that creates a valid split.
P AnalyticalPhysicalCheckDone FailureDefinitionId Analytical / Physical Model Consistency check is complete.
P AnalyticalSupportCycleWarning FailureDefinitionId Circular support chain detected
P AnalyticalSurfaceCannotMove FailureDefinitionId Cannot move analytical surface.
P AnalyticalSurfaceCannotMoveByConnector FailureDefinitionId Cannot move analytical surface because it will disconnect the analytical nodes.
P AnalyticalTopBottomPlanesReversed FailureDefinitionId Analytical Top Projection Plane is partially or completely below Analytical Bottom Projection Plane. Please reset top and/or bottom planes to valid values.
P AutoDetectIgnoreLeaderWarning FailureDefinitionId Analytical Model for Structural Element has reset to its default location.
P BCRehostedFromOpeningToPanel FailureDefinitionId Boundary Conditions were re-hosted from the Analytical Opening to the Analytical Panel during upgrade.
P BoundaryLinesIntersect FailureDefinitionId Boundary lines intersect.
P CannotCreateAnalyticalGeometry FailureDefinitionId Cannot construct Analytical Geometry.
P CannotKeepAnalyticalAdjustment FailureDefinitionId Analytical model Adjustment distance exceeds current Adjustment Snapping Distance. To adjust snap settings, go to the Structural Settings Dialog.
P CannotMakeAnalyticalGeometry FailureDefinitionId Cannot construct Analytical Geometry.
P CannotSlantAnalyticalWallError FailureDefinitionId Cannot slant a wall with an Analytical Model. Please disable the Analytical Model first.
P ContextualAnalyticalModelModeNotEnabled FailureDefinitionId Contextual Analytical Model not enabled. File open was canceled.
P EnterPositiveValueLessThan FailureDefinitionId Please enter a positive value less than [Value].
P HighestAssociatedLevelBelowLowestAssociatedLevel FailureDefinitionId The Highest Associated Level is set below the Lowest Associated Level
P LoadsBCsInnerContoursDeletedDuringSplit FailureDefinitionId During the split process, the interior contours of unconstrained area loads and boundary conditions were removed.
P LoadsBCsOutsideOfHostDuringSplit FailureDefinitionId Loads or Boundary Conditions outside of splited element boundaries will not be modified during split.
P LoadsMayBeNotUpToDate FailureDefinitionId Reactions defined as Internal Load (Is Reaction) may no longer be valid since the analytical model has changed.
P LowestAssociatedLevelAboveHighestAssociatedLevel FailureDefinitionId The Lowest Associated Level is set above the Highest Associated Level
P ProjectionPlaneInvalidWall FailureDefinitionId Projection plane becomes invalid for this wall.
P ProjectionPlanesNotIntersect FailureDefinitionId Can't project Analytical Model. Planes do not intersect each other.
P ProjectionPlanesParallel FailureDefinitionId Can't project Analytical Model. Two or more projection planes are parallel.
P StructAnalyticalErrorProjection FailureDefinitionId Can't project Analytical Model to Analytical Projection Surface
P StructuralElementMayNotBeSupported FailureDefinitionId Structural Element may not be supported -- verify support for Element.
P StructWallAnalyticalErrorAlign FailureDefinitionId Can't align Analytical Model with joined Walls.
P StructWallAnalyticalErrorConversion FailureDefinitionId Can't convert Edges to Analytical Model curves.
P SupportCheckDone FailureDefinitionId Member support check is complete. No unsupported elements detected.
P UnableToUpgradeAnalyticalElementGeometry FailureDefinitionId Unable to upgrade analytical element with incorrect geometry. To keep the elements, open Revit 2022 and correct the elements.
P WallAMLostAdjustmentReference FailureDefinitionId Wall Analytical Model has lost its adjustment reference.