ElectricalFailures

Description:
Failures about Electricity.
Inheritance Hierarchy:
System.Object
  Autodesk.Revit.DB.BuiltInFailures.ElectricalFailures
public static class ElectricalFailures
Name Return Type Description
P AllSlotsOnPanelOccupied FailureDefinitionId All slots on panel: [Panel Name] are occupied. Some circuits will be disconnected from this panel.
P BankDistanceSmallerThanDiameter FailureDefinitionId The distance value is smaller than the conduit diameter, please enter a larger value
P CableTrayModified FailureDefinitionId The cable tray has been modified to be in the opposite direction or insufficient space to create the required fittings.
P CannotAddMorePolesToCircuit FailureDefinitionId Empty slots are unavailable to hold the number of poles you specified for this spare. \nTo add more poles to this spare, you must free up slots by moving the circuits below the spare.
P CannotAssignSecondaryDistSysToCircuit FailureDefinitionId Cannot assign or add [Element] to Circuit. There is no assigned secondary distribution system for [Element].
P CannotConnectDifferentDesignOptsObjects FailureDefinitionId Cannot add or assign [Element] to circuit. Electrical objects belonging to different design options cannot be connected.
P CannotCreatePanelScheduleDuetoNoDefaultTemplate FailureDefinitionId A panel schedule cannot be created for these panels. A default panel schedule template must be assigned for this template type.
P CannotRemoveMembersInCircuitHavingParent FailureDefinitionId You have selected elements that are connected to a Panel object in a Circuit. These elements cannot be removed from the Circuit.
P CircuitOverload FailureDefinitionId Total connected load for Circuit [Name] is exceeding 80% of the defined rating ([Rating Value]).
P CircuitsOverlapAndDeleteSpareSpace FailureDefinitionId More than one Spare/Space falls onto the same slot. These Spares/Spaces will be deleted.
P CircuitsOverlapDisconnectCircuits FailureDefinitionId More than one circuit falls onto the same slot. These circuits will be disconnected.
P ConduitModified FailureDefinitionId The conduit has been modified to be in the opposite direction or insufficient space to create the required fittings.
P ElementsBelongToOtherCircuit FailureDefinitionId You have selected elements that are already part of other Circuits that have assigned Panels. The elements you selected cannot be added to this Circuit.
P FamilyMismatchCircuit FailureDefinitionId The family no longer matches the properties for the Circuit. Disconnect the family from the Circuit?
P FeedThroughLugsIsDisabled FailureDefinitionId The feed through lugs option is unchecked.
P FeedThroughLugsIsNotEnabledAndBindFormulaInFamily FailureDefinitionId Can't change connection type to Feed Through Lugs because Feed Through Lugs is unchecked. Enable Feed Through Lugs with related formula in family editor the Feed Through Lugs is mapped to. Select the panel -> Edit Family -> Family Types.
P FeedThroughLugsIsNotEnabledAndBindGlobalParam FailureDefinitionId Can't change connection type to Feed Through Lugs because Feed Through Lugs is not enabled. Enable Feed Through Lugs by enabling the global parameter that Feed Through Lugs is mapping. Click Manage tab -> Settings panel -> Global Parameters.
P FeedThroughLugsIsOccupiedAndDisconnectOtherCircuits FailureDefinitionId The feed through lugs is occupied, so other circuits connected with feed through lugs will be disconnected from this panel [Panel Name].
P FeedThroughLugsIsOccupied FailureDefinitionId The feed through lugs is in use by circuit [Element].
P InvalidNumberOfCircuitValueForSwitchPanel FailureDefinitionId The number of circuits on the switchboard currently exceeds the value you entered. Reduce the number of circuits on the equipment before changing this value.
P InvalidNumwiresSinglephase FailureDefinitionId Invalid number of wires for single phase, only 2 and 3 are valid.
P InvalidPathOfParallelConduits FailureDefinitionId Invalid path of parallel conduits
P MaximumNumberOfPolesExceeded FailureDefinitionId You cannot add more poles to this spare, as doing so would exceed the maximum number of poles set for this equipment.
P MismatchConnectorDistSysToCircuit FailureDefinitionId Cannot add [Element] to Circuit. The Type for the available connector does not match the Type ([Name]) for the Circuit.
P MismatchNmbAssignedDistSysToCircuit FailureDefinitionId Cannot assign or add [Element] to Circuit. There is no assigned distribution system for [Element].
P MismatchNmbOfPolesToCircuit FailureDefinitionId Cannot add [Element] to Circuit. The Number of Poles for [Element] does not match the Number of Poles ([Name]) for the Circuit.
P MismatchPoleBrakesSlotsNumbers FailureDefinitionId The number of pole breakers may not be less than the number of occupied slots.
P MismatchVoltageLineToLine FailureDefinitionId Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Line Voltage for [Element] (The Line to Line Voltage is specified in the assigned Distribution System).
P MismatchVoltageToCircuit FailureDefinitionId Cannot add [Element] to Circuit. The Voltage for [Element] is out of range for the Voltage ([Voltage Value]) for the Circuit.
P MissingOrInvalidWireSizeTable FailureDefinitionId Wire Size Table "[Fail Name]" is missing or invalid. Use Electrical Settings to select a valid Wire Size Table.
P NoAvailableMatchingConnector FailureDefinitionId Cannot add [Element] to Circuit. There is no available connector matching the Type ([Type Name]) for the Circuit.
P NotAllowedCableTrayConduitRotation FailureDefinitionId Don't allow to rotate a horizontal cable tray/conduit like this
P NotEnoughAvailSlotsAndLugsOnPanel FailureDefinitionId You can't connect to panel [Panel Name] because there aren't enough slots and Feed Through Lugs is occupied.
P NotEnoughAvailSlotsAndLugsOnSwitchPanel FailureDefinitionId You can't connect to switchboard [Panel Name] because there aren't enough space and circuit [Circuit Name] is set to Feed Through Lugs.
P NotEnoughAvailSlotsOnPanel FailureDefinitionId You can't change the connection type to Breakers connect to panel [Panel Name] because there aren't enough slots.
P NotEnoughRoomForParallelConduits FailureDefinitionId Due to changes in elevation, there is not enough room to generate all of the parallel conduits. As a result, some conduit segments have not been generated.
P NotEnoughRoomForParallelPipes FailureDefinitionId Due to changes in elevation, there is not enough room to generate all of the parallel pipes. As a result, some pipe segments have not been generated.
P NotEnoughSlotsOnlyLugAvailableForSwitchPanel FailureDefinitionId There aren't enough space on switchboard [Panel Name], so the circuit will connect through Feed Through Lugs.
P NotEnoughSlotsOnlyLugAvailable FailureDefinitionId There aren't enough slots on panel [Panel Name], so the circuit will connect through Feed Through Lugs.
P NotPositiveBendRadius FailureDefinitionId The value you entered for the bend radius is zero or a negative value. Enter a positive value.
P NotSupportConcentricBend FailureDefinitionId Conduit with Fittings do not support Concentric Bend Radius, the bend radius of the conduit fittings will be same.
P NumberOfCircuitFullOnSwitchPanel FailureDefinitionId You can't change the connection type to Breakers and connect to switchboard [Panel Name] because there aren't enough space. \nYou can increase the number of circuits to be greater than [Number] to connect through breakers.
P ObjsDemolished FailureDefinitionId Cannot assign [Element] to circuit. Objects that are demolished cannot be added to a circuit.
P PanelMismatchCircuitType FailureDefinitionId Cannot assign [Element] to Circuit. The Type for the panel does not match the Type ([Name]) for the Circuit.
P PanelMismatchDistSysWhenCircuitAssigned FailureDefinitionId The selected circuit was added to panel [Element], but the distribution system for the panel does not match the power connector definition on the panel.
P SelectedElementsArePartOfOtherCircuit FailureDefinitionId You have selected elements that are already part of other Circuits. They will be removed from the original Circuits and added to this one.
P SmallBendRadius FailureDefinitionId The value you entered for the bend radius for conduit is too small. Enter a larger value.
P UnsignedCircuit FailureDefinitionId Circuit is not assigned to a panel
P VoltageIsOutOfRange FailureDefinitionId Cannot assign or add [Element] to Circuit. The Voltage ([Voltage Value]) for the Circuit is out of range for the Line to Ground Voltage for [Element] (The Line to Ground Voltage is specified in the assigned Distribution System)."
P WireMaxSizeNonexistent FailureDefinitionId Cannot find max size in current wire type's material table.