RebarSystemFailures
Description:
Failures related to rebar systems.
Failures related to rebar systems.
Inheritance Hierarchy:
System.Object
Autodesk.Revit.DB.BuiltInFailures.RebarSystemFailures
System.Object
Autodesk.Revit.DB.BuiltInFailures.RebarSystemFailures
public static class RebarSystemFailures
| Name | Return Type | Description |
|---|---|---|
| AreaReinforcementOutSideOfHost | FailureDefinitionId | Area Reinforcement is sketched completely outside of its host. |
| AreaReinforcementRegenFail | FailureDefinitionId | Can't regenerate Area Reinforcement. |
| AreaReinforcementsCollision | FailureDefinitionId | Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision. |
| AreaReinforcementWrongHost | FailureDefinitionId | Area Reinforcement can be placed only in Structural Floors and straight Structural Walls. |
| BarsTooCloseNumber | FailureDefinitionId | Bars are too close together. Decrease the Number Of Lines parameter. |
| BarsTooCloseSpacing | FailureDefinitionId | Bars are too close together. Increase the Maximum Spacing parameter. |
| BarsTooSparseSpacing | FailureDefinitionId | Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter. |
| CannotPlaceAreaReinforcement | FailureDefinitionId | Can't find a host for Area Reinforcement. |
| CannotPlaceAreaReinforcementWarn | FailureDefinitionId | Can't find a host for Area Reinforcement. |
| CannotPlaceAreaReininforcement | FailureDefinitionId | Can't find a host for Area Reinforcement. |
| CannotPlaceAreaReininforcementWarn | FailureDefinitionId | Can't find a host for Area Reinforcement. |
| CannotPlacePathReinforcement | FailureDefinitionId | Can't find a host for Path Reinforcement. |
| CannotPlacePathReinforcementWarn | FailureDefinitionId | Can't find a host for Path Reinforcement. |
| CannotPlacePathReininforcement | FailureDefinitionId | Can't find a host for Path Reinforcement. |
| CannotPlacePathReininforcementWarn | FailureDefinitionId | Can't find a host for Path Reinforcement. |
| CannotUseAreaReinforcementHookTypeStyle | FailureDefinitionId | At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles. |
| CannotUsePathReinforcementHookTypeStyle | FailureDefinitionId | At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles. |
| DPartReinfDeletedEditDivision | FailureDefinitionId | Edits to the model will cause some Reinforcement hosted on Parts to be deleted. |
| DPartReinforcementDeleted | FailureDefinitionId | Reinforcement hosted on highlighted Parts will be deleted. |
| HostFlagAreaOff | FailureDefinitionId | |
| HostFlagAreaOn | FailureDefinitionId | The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off. |
| HostFlagPathOff | FailureDefinitionId | |
| HostFlagPathOn | FailureDefinitionId | |
| LessThanTwoBars | FailureDefinitionId | Each reinforcement direction requires at least 2 bars. Please increase the number of bars. |
| PathReinforcementWrongHost | FailureDefinitionId | Path Reinforcement can be placed only in Structural Floors and straight Structural Walls. |
| RebarSystemOffset | FailureDefinitionId | Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate. |
| ThinHostFloorError | FailureDefinitionId | Rebar Cover Top and Bottom are too large for host. |
| ThinHostFloor | FailureDefinitionId | Rebar Cover Top and Bottom are too large for host. |
| ThinHostWallError | FailureDefinitionId | Rebar Cover Interior and Exterior are too large for host. |
| ThinHostWall | FailureDefinitionId | Rebar Cover Interior and Exterior are too large for host. |