2022 Class
Changes 6
C

RebarSystemFailures

Description:
Failures related to rebar systems.
Inheritance Hierarchy:
System.Object
  Autodesk.Revit.DB.BuiltInFailures.RebarSystemFailures
public static class RebarSystemFailures
Name Return Type Description
P AreaReinforcementOutSideOfHost FailureDefinitionId Area Reinforcement is sketched completely outside of its host.
P AreaReinforcementRegenFail FailureDefinitionId Can't regenerate Area Reinforcement.
P AreaReinforcementsCollision FailureDefinitionId Area Reinforcements are colliding. Aligning the Major Directions, or changing the Additional Offsets, can prevent collision.
P AreaReinforcementWrongHost FailureDefinitionId Area Reinforcement can be placed only in Structural Floors and straight Structural Walls.
P BarsTooCloseNumber FailureDefinitionId Bars are too close together. Decrease the Number Of Lines parameter.
P BarsTooCloseSpacing FailureDefinitionId Bars are too close together. Increase the Maximum Spacing parameter.
P BarsTooSparseSpacing FailureDefinitionId Bar spacing is greater than the size of the reinforced region. Decrease the Maximum Spacing parameter.
P CannotPlaceAreaReinforcement FailureDefinitionId Can't find a host for Area Reinforcement.
P CannotPlaceAreaReinforcementWarn FailureDefinitionId Can't find a host for Area Reinforcement.
P CannotPlaceAreaReininforcement FailureDefinitionId Can't find a host for Area Reinforcement.
P CannotPlaceAreaReininforcementWarn FailureDefinitionId Can't find a host for Area Reinforcement.
P CannotPlacePathReinforcement FailureDefinitionId Can't find a host for Path Reinforcement.
P CannotPlacePathReinforcementWarn FailureDefinitionId Can't find a host for Path Reinforcement.
P CannotPlacePathReininforcement FailureDefinitionId Can't find a host for Path Reinforcement.
P CannotPlacePathReininforcementWarn FailureDefinitionId Can't find a host for Path Reinforcement.
P CannotUseAreaReinforcementHookTypeStyle FailureDefinitionId At least one of the bars in the Area Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
P CannotUsePathReinforcementHookTypeStyle FailureDefinitionId At least one of the bars in the Path Reinforcement has a Bar Type or Shape that is incompatible with the Hook type. Check the Hook permissions for the Bar Type (see Hook Lengths) and the Hook and Rebar Shape styles.
P DPartReinfDeletedEditDivision FailureDefinitionId Edits to the model will cause some Reinforcement hosted on Parts to be deleted.
P DPartReinforcementDeleted FailureDefinitionId Reinforcement hosted on highlighted Parts will be deleted.
P HostFlagAreaOff FailureDefinitionId
P HostFlagAreaOn FailureDefinitionId The Area Reinforcement element was created in a document with the Host Structural Rebar setting on, and cannot be transferred into this document, which has the setting off.
P HostFlagPathOff FailureDefinitionId
P HostFlagPathOn FailureDefinitionId
P LessThanTwoBars FailureDefinitionId Each reinforcement direction requires at least 2 bars. Please increase the number of bars.
P PathReinforcementWrongHost FailureDefinitionId Path Reinforcement can be placed only in Structural Floors and straight Structural Walls.
P RebarSystemOffset FailureDefinitionId Rebar Cover Side/Edge is too large for sketch. Bar placement may be inaccurate.
P ThinHostFloorError FailureDefinitionId Rebar Cover Top and Bottom are too large for host.
P ThinHostFloor FailureDefinitionId Rebar Cover Top and Bottom are too large for host.
P ThinHostWallError FailureDefinitionId Rebar Cover Interior and Exterior are too large for host.
P ThinHostWall FailureDefinitionId Rebar Cover Interior and Exterior are too large for host.