2027 Class
Changes 8
C

StairRampFailures

Description:
Failures about StairRamp.
Inheritance Hierarchy:
System.Object
  Autodesk.Revit.DB.BuiltInFailures.StairRampFailures
public static class StairRampFailures
Name Return Type Description
P ActualRiserHeightChanged FailureDefinitionId The actual riser height for one or more stairs violates the maximum set in the type.
P AntiparallelRampRisers FailureDefinitionId Riser lines are parallel but not collinear. Can't build Run between these Risers.
P AntiparallelRampRisersError FailureDefinitionId Riser lines are parallel but not collinear. Can't build Run between these Risers.
P ArcRunRadiusTooSmall FailureDefinitionId Can't create Run. Run radius is too small.
P ArcRunWidthTooLongFailure FailureDefinitionId Arc run width is too long.
P AutomaticLandingConvertedToSketchedLandingWarning FailureDefinitionId Some run(s) are deleted, so automatic landing is converted to sketched landing.
P BadBalustersPerTread FailureDefinitionId Number of Balusters per Tread must be an integer greater than zero.
P BadFillingSpacing FailureDefinitionId Spacing for Excess Length Fill is too small.
P BadRailings FailureDefinitionId Can't create Railings.
P BadRailingsError FailureDefinitionId Can't create Railings.
P BadRailProfile FailureDefinitionId One or more Profile Loops are invalid, probably because of self-intersection.
P BadTreadRiserProfile FailureDefinitionId Tread/Riser profile is invalid.
P BalustersTooClose FailureDefinitionId Baluster Separation must be equal to or greater than the Baluster widths.
P BalustersTooCloseAbsolute FailureDefinitionId Baluster Separation is too small.
P BalusterUpsideDown FailureDefinitionId Top reference is below Bottom reference for one or more Balusters. These Balusters are not created.
P CannotAlignSupportOnPosts FailureDefinitionId Cannot align the support on the posts.
P CannotComputeRailElevation FailureDefinitionId Can't compute elevation profile for one or more Rails
P CannotCreateBaluster FailureDefinitionId Can't create Balusters for given Width and Height.
P CannotCreateBalusterPatterns FailureDefinitionId Can't create Baluster Patterns for Railings
P CannotCreateCornerBalusters FailureDefinitionId Can't create corner Baluster
P CannotCreateLandingStringer FailureDefinitionId Can't create stringer at landing.
P CannotCreateMiddleStringer FailureDefinitionId Can't create one or more Middle Stringers.
P CannotCreateMonolithicStairs FailureDefinitionId Can't make monolithic Stairs.
P CannotCreateNosing FailureDefinitionId Can't create nosing on one or more treads.
P CannotCreateOneOrMoreBaluster FailureDefinitionId Can't create one or more Balusters
P CannotCreateOneOrMoreTreads FailureDefinitionId Can't create geometry for one or more treads.
P CannotCreateOpenMiddleStringers FailureDefinitionId Can't cut open/middle stringers geometry.
P CannotCreateRail FailureDefinitionId Can't create Railing. Thickness of Rail or Balusters might be too small. If you don't want Balusters, specify "None" for Baluster Shape.
P CannotCreateRailGeom FailureDefinitionId Can't create geometry for one or more Rails
P CannotCreateRailWarn FailureDefinitionId Can't create Railing. Thickness of Rail or Balusters might be too small. If you don't want Balusters, specify "None" for Baluster Shape.
P CannotCreateRiser FailureDefinitionId Can't create geometry for one or more risers.
P CannotCreateSideStringer FailureDefinitionId Can't create one or more Side Stringers.
P CannotCreateStairForLevelOverlapping FailureDefinitionId Some of the multistory stairs couldn't be created due to the overlapped levels.
P CannotCreateStringers FailureDefinitionId Can't create stringers geometry.
P CannotDrawStairs FailureDefinitionId Can't make stairs
P CannotDrawStairsError FailureDefinitionId Can't make stairs
P CannotEndWithZeroRiser FailureDefinitionId Can't end Stairs with Riser because Riser Thickness is too small.
P CannotGenerateFaces FailureDefinitionId Couldn't generate surfaces for stairs.
P CannotGenerateFacesError FailureDefinitionId Couldn't generate surfaces for stairs.
P CannotGenerateRamp FailureDefinitionId Couldn't generate surfaces for ramp.
P CannotGenerateRampError FailureDefinitionId Couldn't generate surfaces for ramp.
P CannotMakeLanding FailureDefinitionId Can't make landing.
P CannotOffsetBoundary FailureDefinitionId Can't create Boundary as an offset of Run Curve
P CannotOffsetRail FailureDefinitionId Can't create one or more Rails with desired offset
P CannotPlaceBalusterOffset FailureDefinitionId Can't place Balusters and/or Rails with desired offset
P CannotPlaceBalusterPatterns FailureDefinitionId Can't place Baluster Patterns
P CannotPlaceRailingOnStringerWarning FailureDefinitionId Railing is placed on tread because there is no stringer.
P CannotProcessInStairsSketchEditMode FailureDefinitionId Cannot process when stair(s) in sketch edit mode.
P CannotSplitRailingWithExtensions FailureDefinitionId Railings with extensions cannot be split.
P ContinuousRailFilletCreationError FailureDefinitionId Cannot create specified fillet at rail path corner.
P ContinuousRailFilletCreationParallel FailureDefinitionId Cannot create specified fillet at rail path corner because of the curves are already smoothed.
P ContinuousRailFilletCreationWarning FailureDefinitionId Cannot create specified fillet at rail path corner.
P ContinuousRailGometryCreationFailure FailureDefinitionId Cannot create the continuous rail geometry.
P ContinuousRailNotContinuous FailureDefinitionId The rail is non-continuous.
P ContinuousRailSupportPlacementFailure FailureDefinitionId Cannot place the supports along the rail path.
P ContinuousRailTransitionFailure FailureDefinitionId Cannot create specified transition at rail path turn, hand Rail/Top Rail cannot maintain continuous.
P ExtendBelowBaseGreaterThanLandingBaseElevation FailureDefinitionId Extend Below Base needs to be less than Landing Base Elevation.
P ExtendBelowBaseGreaterThanRunTopElevation FailureDefinitionId Extend Below Base needs to be less than Run Top Elevation.
P FailToReOrientSketchCurvesFailure FailureDefinitionId Failed to orient sketch curves.
P HeightOfRunIsTooSmall FailureDefinitionId Height of run is too small.
P IntermediateLandingHigherThanTopRunFailure FailureDefinitionId Run is reversed.
P InvalidBalustersPattern FailureDefinitionId Invalid Balusters Pattern
P InvalidLocationLineJustificationFailure FailureDefinitionId Modify the location justification to a invalid value.
P InvalidParameters FailureDefinitionId Stairs run or landing has invalid parameter(s).
P InvalidRailProfile FailureDefinitionId Profiles for one or more of the Rails are invalid. Make sure that every used Profile is a closed series of non-intersecting Lines.
P InvalidStairsPathFailure FailureDefinitionId Invalid stairs path provided.
P InvalidStartLevel FailureDefinitionId The start level and end level for this staircase must be at different elevations.
P InvalidStartLevelRamp FailureDefinitionId The start level and end level for this ramp must be at different elevations.
P LandingDepthIsLessThanRunWidthWarning FailureDefinitionId Landing depth is less than run width.
P LandingHeightUnderStairsBottom FailureDefinitionId Cannot make landing because height of landing is equal or less than to bottom height of the stair.
P LandingShapeHandleOnPinnedRunFailure FailureDefinitionId Cannot Drag the automatic landing shape handle control because the connected run is pinned.
P MayUnjoinRailAndSupports FailureDefinitionId Fillet may cause the supports unjoin with the rail.
P MultistoryLevelBelowTopbottomLevel FailureDefinitionId Multistory top level must be above the stair/ramp top and bottom levels.
P MultistoryLevelBelowTopbottomLevelError FailureDefinitionId Multistory top level must be above the stair/ramp top and bottom levels.
P MultistoryStairDoesntReach FailureDefinitionId The multistory stair/ramp could not reach its top level with integral number of flights. Maximum number of flights below the top level is created.
P MultistoryStairsAutomaticLevelLandingsDeleted FailureDefinitionId Level landings are deleted because the connected stairs have been regenerated.
P MultistoryStairsComponentJoinFailure FailureDefinitionId Can't keep elements joined. Avoid converting stairs to skeched-based component in Multistory stairs.
P MultistoryStairsHideTopLevelParameter FailureDefinitionId You have set the stair's multistory top level to None, and Revit will remove this parameter, if you want to create a multistory stair, please use Create Multistory Stair feature.
P MultistoryStandardStairBottomEndExceedsOrNotReach FailureDefinitionId One of the stairs inside multistory stairs bottom ends exceeds or cannot reach the base elevation of the stair.
P MultistoryStandardStairTopEndExceedsOrNotReach FailureDefinitionId One of the stairs inside multistory stairs top ends exceed or cannot reach the top elevation of the stair.
P MultusegmentRampRiser FailureDefinitionId Ramp can't have multisegment Riser.
P MultusegmentRampRiserError FailureDefinitionId Ramp can't have multisegment Riser.
P NoCurvesInRailing FailureDefinitionId Railing Sketch has no Lines.
P NoProfileForRail FailureDefinitionId Must specify Profiles for every Rail.
P NoRailingsStringer FailureDefinitionId Railings and Stringers will not be automatically generated due to bad Runs. This message may be incorrect if you have Edited the Sketch and modified some dimensions.
P NoRisersInPureMonolithicStairs FailureDefinitionId Monolithic Stairs with zero tread thickness can't have risers
P NoRunsRamp FailureDefinitionId Ramp has no Runs. Can't create Ramp.
P NoRunsRampError FailureDefinitionId Ramp has no Runs. Can't create Ramp.
P NotALineRiserRamp FailureDefinitionId Riser line must be a straight line for Ramps.
P NotALineRiserRampError FailureDefinitionId Riser line must be a straight line for Ramps.
P NotchThicknessIsLargerThanLandingWarning FailureDefinitionId The notch thickness is larger than landing.
P NotEnoughRisers FailureDefinitionId Actual Number of Risers is different from Desired Number of Risers. Add/remove Risers or change Desired Number of Risers in Stairs Properties.
P OnlyMonolithicStairs FailureDefinitionId Tread thickness can't be zero for non-monolithic stairs
P PartOfRiserLiesOnBoundaryFailure FailureDefinitionId Part of the riser lies on the boundary is not allowed.
P PathDoesntJoinToBorderRisersFailure FailureDefinitionId Path doesn't join to border risers is not allowed.
P RailCurveTooShort FailureDefinitionId Curve in rail sketch is too short for rail creation and ignored.
P RailingBadOffset FailureDefinitionId An arc in the railing sketch has a radius that conflicts with the current rail widths and offsets. Please either increase the radius or modify rail profiles and offsets.
P RailingCurvesNotSplitRamp FailureDefinitionId The slope of this railing will not parallel the ramp at landings. To get a parallel railing, split the railing sketch at the ends of landings.
P RailingCurvesNotSplitStairs FailureDefinitionId The slope of this railing may not parallel the stairs at runs and landings. To get a parallel railing, split the railing sketch at the ends of landings.
P RailingDoublyConnected FailureDefinitionId Railings hosted on Stairs must form a single, open, connected line.
P RailingNotConnected FailureDefinitionId The Railing line must be a single connected Sketch. If you want separate pieces of Railing, create two or more separate Railings.
P RailPathCloseLoopForExtensionWarning FailureDefinitionId The rail path is closed at the start and end path point for extension creation.
P RailPlacedOutsideOfHost FailureDefinitionId Railings are placed completely outside the host. It may change the adjustment of the railing to the host and its vertical position.
P RailProfileLowerThanFilletError FailureDefinitionId Fillet cannot be created between rail segment since the radius is lower than the profile size.
P RailProfileLowerThanFilletFailure FailureDefinitionId Fillet cannot be created between rail segment since the radius is lower than the profile size.
P RailProfileOpen FailureDefinitionId Open Profile Loop can't be used as a Rail Profile
P RailTypeChangeInconsistancyWarningWithResetBtn FailureDefinitionId Some rail type changes are not consistent with your rail instances customization in this project, you can reset them to make them corresponding with your changes.
P RampDoesntReach FailureDefinitionId The ramp is not long enough to reach the top constraint. Change the slope or increase the length of the ramp.
P RampDoesntReachOffset FailureDefinitionId The ramp is not long enough to reach the top constraint plus top offset. Change the slope or increase the length of the ramp.
P RampLandingNotCreated FailureDefinitionId Beginning of run coincide with the end of previous run. Landing is not created between runs.
P RampRunTooComplex FailureDefinitionId Ramp Run has complex boundary and may produce unreasonable geometry. Split it into few Runs by inserting Riser Lines at the end of each Run and at the beginning of the next one. If you want to create Ramp with arc an straight section you can do it using a Run tool.
P RampStartHigherThanEnd FailureDefinitionId The ramp's base (base level + base offset) must be below its top (top level + top offset).
P RiserCurveTooShort FailureDefinitionId Riser curve is too short to create nosing on it.
P RiserHeightIsTooSmall FailureDefinitionId Riser height is too small.
P RiserIntWithBoundaryMoreThanOnceFailure FailureDefinitionId Riser intersects with boundary more than once.
P RisersAtSameLocation FailureDefinitionId The highlighted risers have the same location along the boundary line. Please move one of the two risers.
P RiserThicknesssResetToZero FailureDefinitionId Monolithic Stairs without Treads can't have Risers. Riser Thickness for Stairs Type was automatically set to zero.
P RunBottomHigherThanTopFailure FailureDefinitionId The base elevation for the run is higher than the top elevation for the run.
P RunBottomUnderStairsBottomFailure FailureDefinitionId Run bottom elevation should not be below the stairs bottom elevation.
P RunIsJoiningLandingWithRiserSoNotchDoesNotWorkWarning FailureDefinitionId Run is joining landing with riser, so notch configuration does not take effect. Try to set run as begin/end with tread to make a notch.
P RunTopLowerThanBottomFailure FailureDefinitionId The top elevation for the run is lower than the base elevation for the run.
P SpiralRunRadiusTooSmallFailure FailureDefinitionId The radius value for the run is too small.
P StairIncompleteFailure FailureDefinitionId Stair element is incomplete, not all components are logic connected.
P StairsActualRiserHeightGreaterThanMaximumFailure FailureDefinitionId Computed actual riser height of stairs is greater than maximum riser height defined in stairs type.
P StairsActualRunWidthLessThanMinimumFailure FailureDefinitionId Actual run width is less than minimum run width defined in stairs type.
P StairsActualTreadDepthLessThanMinimumFailure FailureDefinitionId Computed actual tread depth of stairs is less than minimum tread depth defined in stairs type.
P StairsAlreadyAttachedToCurrentLevel FailureDefinitionId Mutistory Stairs already have a Stair attaching to this level.
P StairsAreUpdatedDueToLevelHeightChange FailureDefinitionId Stair component(s) in the multistory stair are updated due to the level height changes.
P StairsAutomaticLandingLayoutFailure FailureDefinitionId Fail to generate the automatic landing layout
P StairsAutomaticLandingLayoutWarn FailureDefinitionId Fail to generate the automatic landing layout
P StairsBottomEndExceedsOrNotReachWarning FailureDefinitionId Stair bottom end exceeds or cannot reach the base elevation of the stair. Add/remove risers at the bottom end or change base elevation settings in Stair Properties.
P StairsCannotExtendToFloorStructureLayerWarning FailureDefinitionId Stairs cannot extend to floor structure layer.
P StairsCommonRunGenerateLayoutFailure FailureDefinitionId Fail to get base line thus fail to generate run layout
P StairsComponentJoinFailure FailureDefinitionId Can't keep elements joined.
P StairsCrossingRisersDisallowedFailure FailureDefinitionId Crossing risers are not allowed
P StairsGenericFailure FailureDefinitionId Stairs generic failure
P StairsGenericTransformFailure FailureDefinitionId Cannot change base elevation of Stairs
P StairsIllegalDesiredNumRisers FailureDefinitionId Desired Number of Risers is too small. Computed Actual Riser Height is greater than Maximum Riser Height allowed by type.
P StairsInMultistoryExceedTopConstraint FailureDefinitionId Stairs in MultistoryStairs after adjusting still exceed the top constraint.
P StairsOnlySingleBoundaryHasRiserWithBothEndsOnBoundaryFailure FailureDefinitionId Only single boundary case may have riser with its both ends on boundary.
P StairsOtherThan2IntsByRiserAndBoundaryFailure FailureDefinitionId More than 2 intersection points between riser segment and boundary encountered
P StairsPathCopyReferenceLostFailure FailureDefinitionId Some stair paths were not copied because some references were lost.
P StairsPathPositionResetWarning FailureDefinitionId The stairs path doesn't intersect with riser lines.
P StairsRunRunJoinNotAllowedFailure FailureDefinitionId Run-Run join is not allowed of they have same "Start With Riser"/"End With Riser" configuration at the joined end.
P StairsStartHigherThanEnd FailureDefinitionId The stairs' base (Base Level + Base Offset) must be below its top (Top Level + Top Offset).
P StairsStringerCannotBeCreated FailureDefinitionId The stairs stringer cannot be created.
P StairsSubElementsNotConnectedWarning FailureDefinitionId Stair sub-elements are not connected
P StairsSupportOverlapFailure FailureDefinitionId Some supports overlap with others
P StairsSupportTooShort FailureDefinitionId A short support is being created.
P StairsTopEndExceedsOrNotReachWarning FailureDefinitionId Stair top end exceeds or cannot reach the top elevation of the stair. Add/remove risers at the top end or change top elevation settings in Stair Properties.
P StairsTopLowerThanBaseFailure FailureDefinitionId The top of the Stair is lower than the base of the Stair
P StairStringerCantOffset FailureDefinitionId Inside stringer could not be created because of insufficient space. Please disable the inside stringer or decrease its width.
P StairsWinderGenLayoutFailure FailureDefinitionId Fail to generate run layout and then cannot make winder run
P StairsWinderInvalidParamsFailure FailureDefinitionId Cannot create the winder run because some values for the instance properties cannot be satisfied.
P StairsZeroDesiredRisers FailureDefinitionId The number of desired risers for a staircase cannot be 0.
P StringerCurvesNotSplitStairs FailureDefinitionId The slope of stringer may not parallel runs and landings. To get a parallel stringer, split boundary lines at the ends of landings.
P StringerCurveTooShort FailureDefinitionId A piece of boundary is too short to create stringer on it.
P TooShortCurveDowngradeGeometry FailureDefinitionId Curve is too short and may downgrade the geometry.
P TreadDepthBelowMin FailureDefinitionId The Actual Tread Depth for one or more Stairs violates the Minimum Depth set in the type.
P TreadDepthFailsEq FailureDefinitionId The actual tread depth and riser height for one or more stairs of this type violates the stair equation.
P TreadDepthTooBigFailure FailureDefinitionId The tread depth is too large for the spiral run.
P TreadFrontProfileInvalid FailureDefinitionId This profile cannot be used for the front of treads. Please choose a profile composed of a closed loop of lines with exactly one lines coincident with the y-axis. This lines will define the connection of this profile to the tread.
P UnableToCreateMultistoryStairs FailureDefinitionId Unable to create Multistory stairs.
P UnexpectedCurveIntersectionFailure FailureDefinitionId Computing curve intersection and find the invalid result.
P WinderFilletRadiusTooLargeFailure FailureDefinitionId The value for Fillet Radius is too large to satisfy the Minimum Inside Width value.
P WinderFirstLegTooShortOrRunWidthTooGreatFailure FailureDefinitionId The first leg of winder run is too short or the runwidth is too great.
P WinderGenericError FailureDefinitionId Cannot make winder.
P WinderLegIsTooShortFailure FailureDefinitionId A winder leg is too short.
P WinderLegsAngleTooGreatOrRunWidthTooSmallFailure FailureDefinitionId The angle between two consecutive legs are too great or the runwidth is too small.
P WinderLegTooShortOrRunWidthTooGreatFailure FailureDefinitionId One leg of the winder run is too small or the runwidth is too great.
P WinderMinWidthTooLargeFailure FailureDefinitionId The value for Minimum Width on Inside Boundary is too large.
P WinderMinWidthTooLargeForParallelTreadsFailure FailureDefinitionId The value for Minimum Width on Inside Boundary is too large to satisfy the number of Parallel Treads at the Start or End as specified in the Run Instance properties.
P WinderParallelLegsFailure FailureDefinitionId Two consecutive legs are parallel.
P WinderParallelTreadsNumberFailure FailureDefinitionId Cannot satisfy the number of Parallel Treads at the Start or End as specified in the Run Instance properties
P WinderRunCreationFailure FailureDefinitionId The relationship between the current values of Actual Run Width, Minimum Width at Inside Boundary, and Parallel Treads at Start or End does not support the creation of the winder run.
P WinderRunInsideMinTreadDepthFailure FailureDefinitionId Please enter a positive value less than Actual Tread Depth on Stair Path (%Actual Tread Depth%).
P WinderRunInsideWalklineOffsetFailure FailureDefinitionId Please enter a value between 0 and half of Actual Run Width (%1/2 Actual Run Width%).
P WinderRunWidthLessThan2TimesMinWidthFailure FailureDefinitionId The value for Minimum Width on Inside Boundary is too large to satisfy the number of Parallel Treads at the Start or End as specified in the Run Instance properties.
P WinderRunWidthLessThanWalkLineOffsetFailure FailureDefinitionId The value for Run Width is less than two times of value of the inside walkline offset.
P WinderRunWidthOrMinWidthOrTooGreatParallelTreadsFailure FailureDefinitionId The parameter runwidth is great or the parameter min width at inside boundary is too great, or number of parallel treads at both ends is too great.
P WinderRunWidthOrMinWidthOrTooShortFailure FailureDefinitionId The parameter runwidth is too great or the parameter min width at inside boundary is too great, or one leg of winder run is too short.
P WinderSecondLegTooShortOrRunwidthTooGreatFailure FailureDefinitionId The second leg of winder run is too short or the runwidth is too great.
P WinderStraightStepsNumberFailure FailureDefinitionId The current layout cannot allow the specified number of treads. Increase the length of the run leg in the model or reduce the value for Parallel Treads at Start or Parallel Treads at End.
P WinderThirdLegTooShortOrRunWidthTooGreatFailure FailureDefinitionId The third leg of winder run is too short or the runwidth is too great.
P WinderTooManyEndParallelTreadsOrRunWidthFailure FailureDefinitionId The number of parallel treads at end is too great or the run width is too great.
P WinderTooManyParallelTreadsAtEndFailure FailureDefinitionId The number of parallel treads at end is too great.
P WinderTooManyParallelTreadsAtHeadFailure FailureDefinitionId The number of parallel treads at start is too great.
P WinderTooManyStartParallelTreadsOrRunWidthFailure FailureDefinitionId The number of parallel treads at start is too great or the run width is too great.